Cypress Semiconductor /psoc63 /BLE /BLELL /DATA_CHANNELS_H0

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as DATA_CHANNELS_H0

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0DATA_CHANNELS_H0

Description

Data channel map 0 (upper word)

Fields

DATA_CHANNELS_H0

This register field indicates which of the data channels are in use. This stores the information for the upper 5 (36:32) data channel indices. ‘1’ indicates the corresponding data channel is used and ‘0’ indicates the channel is unused. Note: The Data channel map 0 and data channel map 1 are two sets of channel maps stored, common for all the connections. At any given time, only two maps can be maintained and the connections will use one of the two sets as indicated by the channel map index field in the CE_CNFG_STS registers specific to the link. Firmware must also manage to update this field along with the map.

Links

() ()